Home ] [ News ] LinAire Products Page ] Services ] Distributors ] Harness Use List ] Feedback ] Literature Request ][ Search Page ]
[ Picture Gallery ]

News

 

  

 

 

 

Home ] [ News ] LinAire Products Page ] Services ] Distributors ] Harness Use List ] Feedback ] Literature Request ]

 

Table of Contents

CONTACT
  INFORMATION:
  LinAire Engineering 
                                                       LinAire 
DISTRIBUTORS

  Search Web Site

 

Feb 2004

Linaire starts production of LTS-525/A Tester Panel that is equivalent to the KING KTS-153 Tester Panel.  The new panel performs all of the same tests provided by the KING KTS-153.

SEE DETAILS

Nov 2003

New LX-4 Transponder Panel replaces the old LX-3 panel and is backwards compatible with the LX-3 harnesses.

 

Requires a Java Enabled Browser.

 

    Sept 2003


L-260 AUDIO CONTROLLER
TEST PANEL

The new L-260 Audio Controller Test Panel provides for standardized testing of aircraft audio controller and amplifier panels.  This panel is designed with standard tests for checking all makes and models of audio panels.  This replaces the old L-240 panel and cuts testing time significantly.  The new L-260 test for the Pilot, Copilot, Comm, and NAV audio channels are basically the same for all units under test with only the number of channels available changing.  Most of the intercom testing is also standard.  

For more details click HERE.

 

Requires a Java Enabled Browser.

     Aug 2003


LTS-525/A TESTER PANEL

This panel performs the same test as the KTS-153 panel.  Customers can follow the same test procedure forms found in the King maintenance manual.  More details click here .


    Nov 2002

            LH 4 Headset Tester Update:

                We have made a modification to the Mike Level control for the LH 4 when using a power mike.  This modification adds more range of mike bias current/voltage adjustment.  There is a fee of $65.00USD for addition of the modification plus shipping to and from factory.  And if LH 4 is still under warranty we will wave the modification fee.  Drop us an email for shipping instructions and a estimated turn around time.


 

    Oct 2002

           LV 6 panel meter reading.  The LV 6 panel meter indicates microamps current flow thru one  FLAG or DEVIATION load.  The confusion occurs when we get in the habit of thinking of the reading as millivolts.  Of course 100uA thru 1K ohm resistance develops 100mV so its is easy to read it as millivolts.  But remember that the navigation indicator meter movements are current devices.  And now days with electronic displays its millivolts across the load.

            We had to pick one or the other.  Since the old LV 5 used microamp meters and the LV 6 needed to be backwards compatible, the LV 6 meter reads out in microamps.

            When reading the TO-FROM current flow thru a 200 ohm load resistance requires a little math.   Take the reading times 2 then move the decimal point left one place.  (.2 X reading = mV)  950uA=190mV   /  1000uA = 200mV  /  1050uA=210mV
            The decimal point is missing in the formula shown in the LV 6 manual.


 

    Sept 2002

           NEW HARNESSES FOR KING COMM & NAV UNITS

         LT3008   Use on the LT 6 test panel for KY96A, KY97A, KY196A, KY197A

           LT3009   Use on the LT 6 test panel for KY92

           LT3010   Use on the LT 6 test panel for KN53

           LT3011   Use on the LT 6 test panel for KN72

           LT3012   Use on the LT 6 test panel for KT76A, KT78A, KT79

    Aug 2002

        NEW HARNESS FOR COLLINS NAV INDICATOR 331A-3F & 331A-3G

         LVI2119  Use with the LV 6 test panel or the LT 6 test panel.


 

    July 2002

            NEW HARNESS FOR GARMIN 400 AND GARMIN 500 SERIES COM/NAV UNITS.  GPS400, GPS500, GNC420, GNC520, GNS430, GNS530

        LT3007   Use with the LT 6 test panel.   See cable notes (click here)

          LV6120    Use with the LV 6 test panel.

          LVI2106    Used to connect the GARMIN GI102A / GI106A Course Deviation Indicators        on both the LV 6 and LT 6 test panels.

    May 2002

         NEW L240 HARNESS FOR NORTHERN AIRBORNE
         AA12-001
            LAA1122  N.A.T. AA12-001 Compact Audio Controller
            LAA1125  N.A.T. AA80-001/020/060/062 Audio Controller L-240 panel version
            LA2030     N.A.T. AA80-001/020/060/062 Audio Controller LA-6 panel version


    March 2002

     NEW L240 HARNESS FOR KING KMA 28 
      Audio Amplifier/Intercom/Marker Beacon

        LAA1124   KING KMA 28   King's Newest Audio controller

    NEW LXS4 ADAPTER HARNESS  
     LXS9204A  
 This patch allows the operation of the TDR94 with a CTL 92 serial control head when used with the LXS9204 Linaire harness..


    January 2002

      HARNESS LIST UPDATE
      HARNESS NOTES ADDED

                 LAA-1121  DM Systems 437 AMP added.
                 LAA-1123  Northern Airborne AA24-001 Audio controller
                 LA-2028     Bendix VC-401B  Comm Unit
                 LA-2029     Northern Airborne AA34-300 Universal Radio Interface
                 LX-9024     Bendix TR-421B with CD-4221/B control

             Harness and Panel note sheets are being added all the time.   Please email us for any additional information you need.


    October 2001

        New LT 6 COMM/NAV Panel

LTPIX_4.jpg (327360 bytes)
CLICK ON PICTURE TO ENLARGE

                New COMM/NAV panel LT 6 replaces the LT 5 panel.  Provides testing for VHF Comm Remote and Panel mounted units.  Also provides testing of the Nav sections of Comm/Nav units as well as the functions of the LA 6 Light Comm panel and some of the LH 4 panel headset testing functions.   
(Click Here for Details)


    May 2001

                New Meter Calibration Instruction sheets available, click here  Calibration.


    March 2001

            Notice: owners of LinAire LXS 4 panels:

        There has been a problem found with the SDI switch.  This mistake will cause the wrong transponder side to be identified as follows:  ALL CALL position will ID the transponder as XPNDR #1 and the XPNDR #1 position as XPNDR#2 and the XPNDR#3 as ALL CALL.  Also the ON/STBY switch should ground the standby line in the STBY position.  This switch maybe wired backwards. These switches can be rewired in about 5 minutes to match the panel face, see the instructions in UPDATES


    September 2000

        New harnesses available this month for the GTX320 and GTX327 transponders made by Garmin International.  

        The LX9023 harness will operate the GTX320 with the Linaire LX-3B test panel.

        The LX9022 harness will operate the GTX327 with the Linaire LX-3B test panel. 


Notice:  owners of the LinAire LTC6 Control Head:

        There has been a problem found with the LTC6 control head (7064 and below) in that the extended frequency range does not function correctly.  To correct this problem the customer needs to do two things, first:  Return the control head to the factory for modification (please give us a call (1-800-282-2253) before returning so we can provide a fast turn-around), second:  Customer needs to modify the LT5 test panel.

    Returning the control head:
        Pack in suitable box and ship to: 
            Linaire Engineering Inc.
            31014 Ford Road
            Garden City, MI  48135
            U.S.A.

        Customer pays shipping to and from factory.  The modification is free.

    LT5 Test panel requires the following:
        Check for a wire from LT5 P1 panel connector pin 42 wired to P2 (control head) connector pin 21.  This wire must be present for the modified LTC-6 to provide extended frequencies 116.00-117.975 and 140.00-151.975 MHz.  Some LT5 panels have a wire from P1 pin 42 to P2 pin 22, in this case just move the wire at P2 pin 22 to P2 pin 21.

    The following LTC6 control heads have been returned and  corrected.   serial # 7049, 7054, 7061


    August 2000

        New harnesses available this month for the King KMA 26 audio amplifier/intercom/marker beacon receiver and DB Systems Model 437 audio control/amplifier.

        LAA1120 harness will operate the KMA 26 using Linaire's L240 test panel.  This harness comes with a note sheet showing how to use King's test procedure with this harness and the L-240 test panel.  This harness and note sheets can be a timesaver.

        LAA1121 harness will operate the Model 437 audio control/amplifier, DB Systems, using LinAire's L240 test panel.  This harness comes with a note sheet to aid in testing of the Model 437.  


    June 2000

       The new version LA2027 harness for use with the KX 155A and KX 165A Comm/Nav system.  This harness mates the KI 208A and KI 209A indicators with the system.  The harness also provides for the use of the older indicators listed below:
        KI 202, KI 203, KI 204, KI 206, KI 207, KI 208, KI 209

NOTE:
    For customers with the early version without the KI 208A/KI 209A connectors their harness can be sent to the factory for modifying to the updated version for $90.00 .  Customer pays shipping to and from factory.


    April 2000

     LW harnesses modifications for panel lamp power, with LW panels serial number 8700 and up. See UPDATES for more details.
    For LW 4 panels below serial number 8700, Linaire can update your panels to provide panel lamp power for the modified LW harnesses. Call for pricing.


    Nov 1999

    LinAire announces first shipment of the new digital control heads for the LV 6 and LT 5 Test Panels.  Each panel frequency control head provides for the two most used codes.  

The LVC 6 operates 2 of 5 or BCD (King off-set) codes selectable by a toggle switch and thumbwheels. This replaces the old LVC 4 (2X5) and LVC 5 (BCD King off-set) control heads. 

The LTC 6 operates 2 of 5 or BCD codes selectable by a toggle switch and thumbwheels.  This replaces the old LTC 1 and LTC 4 control heads.    


  Avionics Test Equipment Panels and Cables for bench testing of Aircraft Radio, Navigation, Audio Controllers, Radar and more. Linaire Engineering Inc.
Last modified: July 15, 2004