LV6 PANEL CALIBRATION SHEET 1 of  2


NAV FLAG LOAD CALIBRATION CHART
Measure at LV 6 NAV/LOC Flag + and - tip jacks

LOAD
SWITCH
MEASURED LIMITS PASSED
1 LOAD   990 - 1010 OHM  
2 LOAD   495 - 505 OHM  
3 LOAD   329.7 - 336.3 OHM  
4 LOAD   247.5 - 252.5 OHM  
5 LOAD   198 - 202 OHM  

 

 

GS FLAG LOAD CALIBRATION CHART
Measure at LV 6 GS Flag + and - tip jacks
LOAD
SWITCH
MEASURED LIMITS PASSED
1 LOAD   990 - 1010 OHM  
2 LOAD   495 - 505 OHM  
3 LOAD   329.7 - 336.3 OHM  
4 LOAD   247.5 - 252.5 OHM  
5 LOAD   198 - 202 OHM  
 

 

NAV DEVIATION LOAD CALIBRATION CHART
Measure at LV-6 NAV/LOC DEV L and R tip jacks
LOAD
SWITCH
MEASURED LIMITS PASSED
1 LOAD   990 - 1010 OHM  
2 LOAD   495 - 505 OHM  
3 LOAD   329.7 - 336.3 OHM  
4 LOAD   247.5 - 252.5 OHM  
5 LOAD   198 - 202 OHM  
 

 

GS DEVIATION LOAD CALIBRATION CHART
Measure at LV 6 GS DEV U and D tip jacks
LOAD
SWITCH
MEASURED LIMITS PASSED
1 LOAD   990 - 1010 OHM  
2 LOAD   495 - 505 OHM  
3 LOAD   329.7 - 336.3 OHM  
4 LOAD   247.5 - 252.5 OHM  
5 LOAD   198 - 202 OHM  

 

 

TO-FROM LOAD TEST
To measure the TO-FROM flag load select the TO-FROM position on the LV 6 meter switch and check for 200 ohms +/- 2 ohms at the LV 6 tip jacks TO and FROM.
PHONE CHANNEL LOAD
To measure the PHONE CHANNEL load check for 600 ohms +/- 6 ohms between the LA NAV connector pin 6 and the LV 6 tip jack ZZ.  You must have the LV 6 SPEAKER/PHONE switch in PHONE.
If any of the above resistances are out of limits you need to replace that resistor.
See the LV 6 Panel Meter Calibration Sheet next to continue with LV 6 Panel calibration.    NEXT
 
 
  Avionics Test Equipment Panels and Cables for bench testing of Aircraft Radio, Navigation, Audio Controllers, Radar and more. Linaire Engineering Inc.