LT 3001 NotesCABLE NAME: LT3001 UNIT UNDER TEST: KX 155, KX 165 ADVANTAGES OF
USING NEW LT 6 PANEL AND HARNESS: POWER
REQUIREMENTS: OPERATIONAL NOTE: because these units share the power input pins with the Remote Transfer function pins a 14/28 volt select switch is located on the Linaire test harness. You MUST select the correct voltage on this switch and also on the LT 6 panel 14/28 volt switch for correct operation. SWITCH IDENTIFICATION: 14/28
VOLT Panel switch: Selects
operating voltage of Unit Under Test POWER/OFF Connects selected DC power to Unit Under Test TEST/NORM Select NORM and leave in NORM except when testing a mike or headset. ICOM/COM Select COM to apply LT 6 panel Mike Jack to Comm units mike input. Select ICOM to apply Mike Jack to the units Intercom input. AUX/COM Select COM to apply Comm Audio or AUX for NAV Audio to panel phone channel. Output is available at LT 6 panel Phone Jack and at panel speaker when selected. SPEAKER/MUTE/PHONES KEY/OFF Select KEY when not using a mike to key the Comm unit under test. VOLUME Set to full CW when measuring the COM or AUX (nav) Audio RMS or when using a watt meter at the phone jack. Otherwise, adjust for comfortable level for ears. SQUELCH The Squelch Adjust is not used on these units under test. SQUELCH
DISABLE DEVIATION
LOAD FLAG LOAD Select 3 loads. The LT 6 NAV DEV L and R lines will have a total of three 1000 ohm loads. If the unit under test has a Glideslope receiver place a 165 ohm 1% resistor across the LT 6 GS FLAG + and - tip jacks for a total of nine 1000 ohm loads. TO-FROM Flag load depends on the customer set-up of the LT 6 panel for OBS signals. If using a precision track selector or a indicator with TO-FROM flag you have one load connected and with the LT 6 Meter switch set to TO-FROM the panel adds one load. To test a three loads you may need either no extra loads or add a 100 ohm 1% resistor (two loads) or 200 ohm 1% resistor (one load) across the LT 6 TO-FROM tip jacks. S1 SWITCH Used as the NAV Transfer button, switch to position P1 and back to OFF. S2 SWITCH Used as the Comm Transfer button, switch to position P1 and back to OFF. PANEL METER Meter can be used to monitor the following: DC Volts applied to the unit, DC Current draw of unit, RMS Volts of Comm audio, RMS Volts of AUX (nav) Audio, Nav Deviation and Flag outputs, Glideslope Deviation and Flag outputs and the TO-FROM flag.
SPECIAL OPERATION NOTES: ALWAYS MAKE SURE TO SET THE VOLTAGE SELECT SWITCHES TO THE CORRECT OPERATING VOLTAGE FIRST. BOTH THE CABLE 14/28VDC AND PANEL 14/28VDC SWITCHES BEFORE APPLING POWER. |
Avionics Test Equipment Panels and Cables for
bench testing of Aircraft Radio, Navigation, Audio Controllers, Radar and more.