While the DME 42 runs with IND 42 indicator it can also operate the 339F-4.
INDICATOR NOTES:
339F-12
When using the frequency hold function use the LD panel switches Range
Override and Standby Override in the ON position to place the unit under test in
the normal Frequency Selection Mode. To place the unit in the frequency Hold
Mode position the Standby Override switch in the OFF position.
339F-12A/12B/12C
When using the frequency hold function use the LD panel switches Range
Override and Standby Override in the ON position to place the unit under test in
the normal Frequency Selection Mode. To place the unit in the frequency Hold
Mode position the Range Override switch in the OFF position.
339F-12A/12C Only the Nav 1 Frequency Selection is connected, Nav 2 is not selectable.
DME 42
When using the frequency hold function use the LD panel switches Range
Override and Standby Override in the ON position to place the unit under test in
the normal Frequency Selection Mode. To place the unit in the frequency Hold
Mode position the Standby Override switch in the OFF position.
Accessory Box Switches apply only to the DME 42. The following list the switches and tip jack use.
|